Ductwork Air Flow Tips

By Tim Carter
©1993-2008 Tim Carter

Summary: If you have an existing house with air conditioning problems, there may be numerous things that are contributing to the problem. We have already discussed the sizing of the air conditioning units and importance of proper return air. But there are other HVAC problems that can cause poor cooling. One of these is static pressure.

 

Static Pressure - Not Electricity

If you have an existing house that has cooling problems, there may be numerous things that are contributing to the problem. We have already discussed the sizing of the air conditioner and importance of proper return air. But there are other problems that can cause poor cooling. One of these is static pressure.

If you are healthy, did you know that your blood pressure is very nearly the same at your heart as it is in the last digit of your index finger? Why doesn't the pressure drop as the blood goes way out to your finger? That's easy. Your blood vessels get smaller and smaller the farther away from your heart. At each bifurcation (a "fork" - where a single vessel splits into two vessels), the two new vessels are smaller than the original. This is because the energy to push the blood has now been split. If you kept one vessel the same size as the original, there would be less energy to push the same amount of remaining blood!

This is the same thing that must be considered with the air in your ducts. The air which is flowing from a duct near the furnace should have very nearly the same force as one which is far away. Take a look at your ducting system if it is visible. You will notice a large trunk line which comes off the furnace. Sometimes it will split and go two directions. These should be smaller than the original. Then, notice how every so many feet, a pipe is branched off to go to a room(s). Does the trunk line get smaller? If it doesn't, especially after two branches, you could have a static pressure problem.

Gentle Turns

While you are looking at your ductwork, pay attention to how the branch lines come off the main trunk line. Are they abrupt 90 degree bends? Or, do they resemble an exit ramp from an expressway? You are looking for exit ramps or wye fittings. These fittings allow the air to change direction in a gentle fashion. Abrupt fittings absorb energy and cut down on the air flow.

Are there lots of turns or 90 degree turns in a branch? Remember, each bend absorbs energy. Turns or bends in ductwork should be minimal.

The A Coil - Dirt Catcher

We discussed earlier that you really have two coils as a part of a central AC system. One is outside you house. It dissipates the heat into the atmosphere. The other coil is inside your extended plenum at your furnace or air handler. This is the coil that gets cold. It cools down the recirculating air inside of your house. Well, guess what? Most people can't see this coil. It is hidden behind the plenum sheet metal. What happens if you still use those worthless fiberglass filters? That's right, this hidden coil can get covered with dirt. If it does, its ability to cool the air is significantly diminished. Buy, use, and regularly clean either high quality paper air filters or a rinsable polyester filter like I have in my furnace. Electronic air filters work very well too.

Helping Your Air Conditioner

The next time hot weather hits, I want you to touch the ceiling of your second floor rooms at about 5 o'clock in the afternoon. Pretty warm aren't they! In fact, these ceilings can radiate vast amounts of heat into your house. Why not reduce the amount of heat in your attic? This will really help your AC.

Install one or more thermostatically controlled attic fans. These devices turn on and off automatically. They exhaust hot air from your attic space. If you install some excellent soffit vents so that cooler (90 degree vs. 150 degree or more) air is being introduced into your attic, you will go a long way in helping your air conditioner.

Reflective Foil Sheathing

Have you seen the foil faced foam sheathing that we builders use on new homes or room additions? Did you ever think how that stuff could work to bounce the radiant energy back towards your roof? Trust me, it works well. You can buy this stuff and cut it into 2 foot by 8 foot sheets that possibly can be inserted through your attic access panel. Staple or nail these to the bottom of your attic roof rafters. If you have little gaps here and there, it is not important. The more aluminum that faces towards the roof, the better.

Continuous Fan Movement

Several readers have contacted me about success they have had by allowing their furnace motor to run continuously. They indicate that this seems to balance the room temperature. No doubt this is true. The air movement also helps to evaporate your own perspiration. Evaporation is a cooling process in and of itself. That is why you feel more comfortable when a breeze blows. Look at your thermostat. There is a little switch that says "On, Off, Auto". Switch it to "On" for continuous fan blowing.



 


Comments:

Vitaliy
26 May 2008, 02:46
Hi.
In this article you mention "Install one or more thermostatically controlled attic fans" but in your article about "Powered Attic Fans - Attic Insulation Fans" you say to stay away from these because they pull a/c from inside your house making your a/c unit work harder and also that it can pull combustible gases. I'm confused. I'm trying to read through these and figure out what I can do about our current situation and it's getting me more confused.
Our home is in Tulsa, OK and it has started to be really hot here in the past week or so. We moved into this house in November (new construction), so this will be the first time we are actually running the a/c. The outside temperature today was mid 80s and just a bit humid. It is 2am right now and inside 1st floor is showing as 82 and is more humid than outside. Inside 2nd floor is showing 87 and is more humid than 1st floor. And I was up in the attic yesterday and it was probably around 150. We have tried running the a/c and the temperature doesn't go down. I'm going to be calling an HVAC person tomorrow to see if they can check maybe the a/c was never filled with refrigerant and needs to be filled.
As far as I can see, we have 4 separate air handlers and a/c units and only 1 air return for each unit and 1 or more air outlets in each room and hallways (depending on how big room is). The air returns are all located in hallways just off of the bedroom and living room. 2 of the air handlers are in the attic, 2 are on the 1st floor inside closets. The attic floors seem to be insulated pretty well with sprayed batting and roof does not have any insulation or deflectors or anything.
It gets well over 100 here in Oklahoma. What can I do to remedy our situation?
Thank you for your help

     View all comments
*Name:
Email:
Notify me about new comments on this page
Hide my email
*Text:
Security Image:

Visual CAPTCHA


 
 
Contact us to Advertise on this site.
Have a Suggestion?

Ask the Builder Comment Help

Helpful Comment Tips: If you need help with a problem, please try these things now before you type in a comment. You could discover your answer in just minutes.
Don't show this alert again.