AquiPor Porous Concrete Questions
AquiPor Porous Concrete Questions - Only Time Will Tell
I received an email from Greg Johnson on September 16, 2026. His signature tag indicated he was the CEO and Co-Founder of Aquipor. Here's what he sent me:
Hi ,
I wanted to invite you to a small technical session I’m hosting for people in the concrete, infrastructure, and related industries.
AquiPor has developed a patented technology that transforms conventional concrete into a permeable surface with sub-micron porosity, allowing stormwater to pass through the concrete while filtering pollutants at the surface.
Rather than doing a typical webinar, I want to keep these sessions small and conversational.
I’ll spend about 15 minutes showing you:
- How the technology works
- What makes AquiPor different from traditional pervious concrete
- What we’ve learned from our latest real-world installations
- Where we’re headed next
Then we’ll open it up for Q&A. If you have technical questions about the material, manufacturing, installation, performance, or commercialization, you’ll be able to ask me directly.
This summer we completed our largest project to date, roughly 3,000 square feet of AquiPor porous pavers at the Estates at Farragut. The project also demonstrated that AquiPor can fit into existing concrete manufacturing and installation workflows.
I’m hosting two sessions:
Tuesday, September 22 - 11:30 AM PT (2:30PM ET)
Thursday, September 24 - 3:00 PM PT (6:00PM ET)
Choose the session that works best for you → Register Here - (I disabled the link for all the obvious reasons)
I’d be glad to have you there.
Greg Johnson
AquiPor Technologies, Inc.
Cofounder | CEO
# # #
You can visit the Aquipor website and view a video of a slab of concrete soaking up water like a sponge.
I responded the next morning, saying:
Greg,
My college degree is in geology with a focus on hydrogeology.
While Aquipor appears to be a magic product, there's nothing on the website describing how it maintains the clear pathway from the surface to the underslab layer of soil. How exactly will fine silt and clay particles that enter Aquipor be removed? The concrete matrix will eventually clog just like any other filter.
Once this happens, your Aquipor will act like normal concrete, not allowing water to pass through the matrix.
That's not going to happen with Aquipor. Prove me wrong.
I've yet to receive a reply from Mr. Johnson as of September 18, 2026.
On September 25, 2026 Mr. Johnson replied. His response is just below.
These are the questions I'd ask Mr. Johnson if I were to interview him:
What happens if the subsoil under your Aquipor concrete is a dense clay? Will the clay block the downward movement of water resulting in overland flow of stormwater across the concrete?
Air, oil, and water filters clog with debris, dust, dirt, etc. Some can be cleaned, but most are disposed of and a new filter is installed. Aquipor appears to be a concrete filter. How will one clean the accumulated dirt and debris out of the concrete?
What kind of long-term testing was done to show that Aquipor continues to soak up water at the same rate as the day after it was poured? Can you share who did the testing as well as the test results?
Those are just a few of the questions I'd ask. What kind of questions can you come up with? Just put them in the comments.
Here's Mr. Johnson's reply:
Hello Tim,
Thank you for the questions, and I'm sorry my reply is late. Been on the road and catching up now. You're right that AquiPor is a filter and filters load up. Below is what our independent test data shows, including some responses to your questions. I'm happy to send the full reports.
1. How does water get through, and what happens to silt and clay? AquiPor isn't pervious concrete. It has a finished surface, and water moves through a fine, tortuous pore network, not through open macro-voids. The technology is a chemically bonded porous ceramic material that we process as a finely milled additive. The additive particles themselves are highly porous: AET's ASTM C128 test measured 11.3% absorption, with a bulk specific gravity of 2.30 against an apparent specific gravity of 3.11, which works out to about 26% internal pore volume. In our finished concrete samples, AET's ASTM C642 test measured 18.8% permeable pore space against and 8.1% absorption.
In Evergreen StormH2O's column study (Report 25013, March 2026), the saturated infiltration rate was 1.37 in/hr. What’s different about AquiPor vs. pervious concrete though, is that our surface has rapid uptake, but the concrete detains and slowly releases that water at a rate that is closer to a sandy loam. The 1.37 in/hr. rate is based on the ASTM C1701 standard for pervious concrete, which only tells half the story of how our concrete works hydrologically. Next test for us is sorptivity via ASTM C1585. Also unlike pervious concrete, fines are captured mainly at the surface of our concrete, not in the matrix. TSS removal averaged 96.8% (113 mg/L in, 3.6 mg/L out) over eight events.
2. What about a dense clay subsoil? Your concern is valid. Evergreen's report states that when the native soil infiltrates more slowly than the pavement's design rate, the soil rate governs. Over clay, AquiPor has to be designed as filtration plus detention, with an aggregate reservoir, an underdrain and an overflow, not as full infiltration. That adds design costs and engineering complexity, where AquiPor may not be the best fit.
In short, on impermeable or very low-permeability clay, I would not design AquiPor as a “pavement that infiltrates into the native soil.” I would design it as a lined or partially lined, underdrained permeable pavement detention & treatment system so that water enters through the AquiPor surface, is stored and filtered in an open graded aggregate reservoir, then releases at a controlled rate to a downstream approved stormwater system.
3. How is it cleaned? AquiPor’s pore size will block most particulates and TSS at the surface. Over time this debris will accumulate. In our testing under loading about twice typical residential TSS, the infiltration rate fell from 1.37 to 0.29 in/hr. after accumulation. Power washing brought it back to 0.95 in/hr. With these numbers, we set a 0.5 in/hr design rate as the maintenance trigger. That is reached at about 225 g/m² of accumulated fines, which is roughly 31 inches of rainfall at a 1:1 run-on ratio in residential areas. Currently our recommended maintenance is regenerative-air or vacuum sweeping, or pressure washing.
4. What long-term testing has been done? There's no multi-year field data yet but we’re working on that now that we have field installations. We’ve been monitoring the demonstration projects in the lay down yard at the precast plant we’re piloting out of, but our next steps are TAPE pilot-level field monitoring, and periodic field infiltration testing of our installations, including the 3,000 sq ft Estates at Farragut installation. We'll publish those results as we get them.
Other results
•Production Holland pavers (Budinger & Associates, ASTM C140, 2026) averaged 5,640 psi gross and 5,880 psi net compressive strength, with a density of 124.1 pcf.
•6PPD-quinone removal was 81.6% (76 to 14 ng/L). This was one paver in one natural-stormwater event, so it's preliminary.
•In the deionized-water flush test, effluent Cu, Zn, total phosphorus, oils and TSS were all below TAPE's typical influent ranges. Effluent pH was 9.9, which is typical of young cementitious material, and it needs to be confirmed in the field.
Happy to coordinate a call with you and our engineers at some point down the road if you're interested.
Appreciate your skepticism. It helps make us sharper!
Thank you,
Greg
Kenny Chesney wrote a song about my skepticism. Listen to the lyrics:
Tim built custom homes and did ultra-custom remodeling for 20+ years before launching his Ask the Builder media presence. He was selected as one of the Big 50 by Remodeling magazine in 1993. This award gave birth to Ask the Builder in October 1993. Tim also operates https://DrawPlumbingPlans.com. His @askthebuilder YouTube channel was the first home improvement channel on YouTube.
Exactly what I was thinking. Keep up the good work
TNX as we say in Morse.
Re Aquapor, is it more susceptible to the growth of moss, mold, etc., since it's porous and might provide a welcoming environment?
Read ALL of my past columns about what fuels algae and mold growth outdoors.
Tim
What does the Aquipor do to the strength of the concrete and what prevents the ground water from back flowing up thru the concrete
How will it work in South Carolina where they just place driveways on sand No gravel.
Oldoc
Strength is a function of the cement content. Period.
Will it survive freeze/thaw cycles?
Listen to what Kenny says in the video just above.
I have a friend in the swimming pool business. He asked me if I would be interested in occasional taking remnant quantity of paint off his hands (less than gallon) for use in painting my basement floor. Sounds good, It will seal the concrete and make it waterproof (like a swimming pool) but is this a good idea? or should the floor breathe? My basement is dry except in the hot summer when humidity condenses on the cool walls. What do you think?
I would NEVER paint a maintenance-free surface.